ANTMINER S19 HYDRO – 184TH/S

1,499.00

Availability: In Stock
Category:
Share:

Product Glance

Value

Version S19 Hydro
Model 208-A
Crypto Algorithm/Coins  SHA256/BTC/BCH
Hashrate, TH/s 132 ± 3%
Power on Wall@Tj65℃, Watt 4554 ± 5%
Power Efficiency on Wall@Tj65°C, J/TH

34.5 ± 5%

Detailed Characteristics

Value

Power Supply
Power Supply AC Input Voltage, Volt(1-1) 342~418
Power Supply AC Input Frequency Range,Hz 47~63
Power Supply AC Input Current, Amp(1-2) 10(1-3)
Hardware Configuration
Network ConnectionMode RJ45 Ethernet 10/100M
Miner Size (Length*Width*Height, w/o

package), mm(2-1)

197*208.6*412
Miner Size (Length*Width*Height, with  package), mm 570*316*430
Net Weight, kg(2-2) 15.8
Gross Weight, kg 17.7
Environment Requirements
Operation Temperature, °C 0~40
Storage Temperature, °C -20-70
Operation Humidity(non-condensing), RH 10~90%
Operation Altitude, m(3-1) ≤2000

*Notes:

(1-1)Caution: Wrong input voltage may probably cause miner damaged

(1-2)Maximum power consumption on the wall: 40°C ambient temperature, 0m above sea level

(1-3)Three-phase AC input, 10A per wire

(2-1)Including power supply dimensions

  (2-2)  Including the weight of the power supply

  (3-1)  When the altitude of the mining machine working site is 900m to 2000m, the maximum operating             temperature will decrease by 1 degree Celsius for every 300m of altitude.

Specifications


 

Product Glance
Model S19 Pro Hyd.
Algorithm | Cryptocurrency SHA256 | BTC/BCH/BSV
Hashrate, TH/s 184 ±3%
Power on wall @35°C, Watt(1-1) 5428 ±5%
Power efficiency on wall @35°C, J/TH(1-1) 29.5 ±5%
Detailed Characteristics
Power Supply
Power supply AC Input voltage, Volt(2-1) 342~418
Power supply AC Input Frequency Range, Hz 47~63
Power supply AC Input current, Amp(2-2) 30
Hardware Configuration
Networking connection mode RJ45 Ethernet 10/100M
Miner Size (Length*Width*Height, w/o package),mm 336*175.5*208
Miner Size (Length*Width*Height, with package),mm 570*316*430
Net weight, kg 13.0
Gross weight, kg 15.6
Environment Requirements
Operation temperature,°C(2-3) 0~40
Inlet water temperature,°C 20-40
Water flow L/min 8±10%
Water pressure bar ≤3.5
Storage temperature, °C -20~70
Operation humidity(non-condensing) , RH 10~90%

NOTE:

(1-1) Inlet water temperature

(2-1) Caution: Wrong input voltage may probably cause miner damaged

(2-2)Three-phaseAC input wires, 10A per wire

(2-3)Operation altitude is recommended below 2000m

There are no reviews yet.

Only logged in customers who have purchased this product may leave a review.